Comparison of Central Corneal Thickness Measurements by Ultrasound Pachymetry and Non-Contact Specular Microscopy in Normal Eyes
Main Article Content
Abstract
Central corneal thickness measurement plays a crucial role in the assessment and treatment of glaucoma and several corneal diseases in addition to its importance in refractive surgery management. There are various methods for central corneal thickness measurement, which differ in their operating principles and technology beside the difference in their advantages and limitation. This study aims to compare central corneal thickness (CCT) values of healthy eyes measured by two common devices: ultrasound pachymetry (UP) and non-contact specular microscopy (NCSM) and to determine the average difference between the two measurements. The study was conducted in the ophthalmology outpatient clinic in Imam Al-Sadiq Hospital- Hilla city and included 99 healthy individuals (198 eyes) of both genders. Results indicated that NCSM tends to give thinner CCT values compared to UP while providing quicker, safer and more comfortable evaluation for corneal thickness in addition to corneal endothelial cell density.
Article Details

This work is licensed under a Creative Commons Attribution 4.0 International License.
References
Jirsova, K. (2017). The cornea, anatomy and function. In Light and Specular Microscopy of the Cornea (pp. 1–20). Springer. https://doi.org/10.1007/978-3-319-48845-5
Navaratnam, J., Utheim, T., Rajasekhar, V., & Shahdadfar, A. (2015). Substrates for Expansion of Corneal Endothelial Cells towards Bioengineering of Human Corneal Endothelium. Journal of Functional Biomaterials, 6(3), 917–945. https://doi.org/10.3390/jfb6030917
Kawana, K., Tokunaga, T., Miyata, K., Okamoto, F., Kiuchi, T., & Oshika, T. (2004). Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis. British Journal of Ophthalmology, 88(4), 466–468. https://doi.org/10.1136/bjo.2003.030361
Piotrowiak, I., Soldanska, B., Burduk, M., Kaluzny, B. J., & Kaluzny, J. (2012). Measuring corneal thickness with SOCT, the Scheimpflug system, and ultrasound pachymetry. ISRN Ophthalmology, 2012, 1–5. https://doi.org/10.5402/2012/869319
Jones, L. W., Srinivasan, S., Ng, A., & Schulze, M. (2018). Diagnostic Instruments. In N. Efron (Ed.), Contact Lens Practice (Third Edit., pp. 327-345.e5). Elsevier Ltd. https://doi.org/10.1016/b978-0-7020-6660-3.00036-8
Mohan, S., Anand Aggarwal, Vanathi, M., & Panda, A. (2007). Pachymetry?: A review. DOS Times, 12(April), 19–28.
Al-Ageel, S., & Al-Muammar, A. M. (2009). Comparison of central corneal thickness measurements by Pentacam, noncontact specular microscope, and ultrasound pachymetry in normal and post-LASIK eyes. Saudi Journal of Ophthalmology, 23(3–4), 181–187. https://doi.org/10.1016/j.sjopt.2009.10.002
Babbar, S., R Martel, M., & B Martel, J. (2017). Comparison of central corneal thickness by ultrasound pachymetry, optical coherence tomography and specular microscopy. New Frontiers in Ophthalmology, 3(3), 1–6. https://doi.org/10.15761/nfo.1000164
Çevik, S. G., Duman, R., Çevik, M. T., Kivanç, S. A., Akova-Budak, B., Perente, I., & Duman, R. (2016). Comparison of central corneal thickness estimated by an ultrasonic pachymeter and non-contact specular microscopy. Arquivos Brasileiros de Oftalmologia, 79(5), 312–314. https://doi.org/10.5935/0004-2749.20160089
Rheima, A. M., Hussain, D. H., Almijbilee, M. M. A., & Abbas, Z. S. (2022). Zinc Oxide Nanotubes?: Synthesis , Diagnosis and Study the Adsorption Ability of Mercury and Lead Ions from Their Aqueous Solutions. Journal of Advanced Sciences and Nanotechnology, 1(1), 20–36. https://doi.org/10.55945/joasnt.2022.1.1.20-36
Garcia-Medina, J. J., Garcia-Medina, M., Garcia-Maturana, C., Zanon-Moreno, V., Pons-Vazquez, S., & Pinazo-Duran, M. D. (2013). Comparative study of central corneal thickness using fourier-domain optical coherence tomography versus ultrasound pachymetry in primary open-angle glaucoma. Cornea, 32(1), 9–13. https://doi.org/10.1097/ICO.0b013e318242fd0f
Módis, L., Szalai, E., Németh, G., & Berta, A. (2010). Evaluation of a recently developed noncontact specular microscope in comparison with conventional pachymetry devices. European Journal of Ophthalmology, 20(5), 831–838. https://doi.org/10.1177/112067211002000504